insulation materials other than those mentioned in 17 06 01 and 17 06 03

Waste catalogue code1 listing

Identification table for code 17 06 04

EWC code
17 06 04
Hazardous
No
Sub-chapter
17 06 — Insulation materials
Common name
Insulation from construction sites, glass and rock wool, removed insulation boards.
Who produces it
Renovation and energy retrofit firms, demolition, installers of external insulation and roofing, building services contractors.
Examples
Mineral wool boards, expanded and extruded polystyrene, polyurethane, wood fibre and cork, offcuts from installing external thermal insulation.

Code 17 06 04 covers insulation materials leaving a site that contain neither asbestos nor dangerous substances: glass and rock wool boards, expanded and extruded polystyrene, polyurethane, wood fibre, cork, offcuts from installing external insulation. It sits in sub-chapter 17 06, which groups insulation and asbestos-containing materials, and it is reached by exclusion: the entry itself says other than those mentioned in 17 06 01 and 17 06 03.

As of 25 November 2026, Sfridoo has 1 published listing with waste code 17 06 04. By legal classification: 1 as waste. Most frequent province: Perugia (1).

Both mirror entries are hazardous: 17 06 01* is insulation containing asbestos, 17 06 03* gathers other insulation materials consisting of or containing dangerous substances. This is where checking matters. Mineral wools are classified according to the notes of Regulation (EC) No 1272/2008 on fibre biosolubility, and a board removed from an older building may not meet them; polystyrene with the flame retardant HBCD falls under Regulation (EU) 2019/1021 on persistent organic pollutants. Insulation removed in energy retrofits is a small, bulky part of the 862.2 million tonnes of waste that construction generated in the EU in 2022, according to Eurostat.

Insulation is the site fraction with the hardest recovery: light, bulky, often glued or faced. There are chains for returning mineral wool to production and for recycling clean polystyrene, through R5 or R3 operations depending on the material. Site insulation rarely becomes a by-product under Article 5 of Directive 2008/98/EC, and end-of-waste status under Article 6 goes through case-by-case recovery at a permitted plant. As waste, it moves under the rules of the Member State where it is located, within the Waste Framework Directive, Directive 2008/98/EC: whoever collects or transports it professionally is registered under Article 26, the receiving plant holds a permit under Article 23 or an exemption under Articles 24 and 25 where the Member State provides one, and the load travels with the transport document required by national rules. Plants that treat it keep the chronological record of Article 35 — quantity, nature, origin, destination and treatment method — which Member States may run as an electronic registry; whether the producer of non-hazardous waste keeps one too, and what is reported each year, is set by the Member State.

Published listings

Frequently asked questions

  • Who collects insulation under code 17 06 04?

    Code 17 06 04, insulation materials from building sites containing neither asbestos nor dangerous substances, is collected by plants sorting construction waste, mineral wool manufacturers taking back their own scrap, and polystyrene recyclers for clean, separated material. Recovery takes place under operation R5 or R3 depending on the material, and what finds no chain goes to disposal. Insulation mixed with rubble or membranes loses almost every recovery chain, and the same applies to glued or faced boards. Whoever offers a lot helps the buyer assess it by stating the type of insulation and whether it is dry and separated by material.

  • How do you tell whether mineral wool is 17 06 04 or 17 06 03*?

    Whether mineral wool is 17 06 04 or 17 06 03* is established from the product documentation or from an analysis: fibres that meet the biosolubility criteria in the notes of Regulation (EC) 1272/2008 are not classified as hazardous. More recent products may carry a certification attesting it, while for a board removed from an older building neither may exist; in that case the prudent classification is the hazardous entry, 17 06 03*. The assessment is made by the waste producer, and it is best made before removal, because it changes how the material is dismantled and packed.

  • Can insulation with asbestos go here?

    Insulation with asbestos can never go under 17 06 04. Insulation containing asbestos has entry 17 06 01*, and other construction materials containing asbestos entry 17 06 05*; their removal follows its own rules, with licensed firms and a work plan drawn up before the work starts. The asbestos question is settled before dismantling, not after, with sampling and an analysis when the building is old or documentation is missing. Polystyrene with the flame retardant HBCD also needs a separate assessment, because it falls under Regulation (EU) 2019/1021 on persistent organic pollutants.