EWC code 15 01 10*
packaging containing residues of or contaminated by dangerous substances
Identification table for code 15 01 10*
- EWC code
- 15 01 10*
- Hazardous
- Yes: entry marked with an asterisk
- Sub-chapter
- 15 01 — Packaging
- Common name
- Contaminated packaging, soiled drums and jerrycans, containers with hazardous residue.
- Who produces it
- Chemical and paint industry, workshops and maintenance, agriculture, food and pharmaceutical industry, construction sites.
- Examples
- Drums and jerrycans with solvent or paint residue, plant protection product containers, additive sacks, unemptied adhesive pails.
EWC code 15 01 10* identifies packaging containing residues of or contaminated by dangerous substances: drums and IBCs with solvent, paint or oil heels, chemical jerrycans, plant protection product containers, additive sacks, unemptied adhesive pails. It sits in chapter 15 of the European List of Waste (Decision 2000/532/EC), waste packaging, absorbents, wiping cloths, filter materials and protective clothing, and in sub-chapter 15 01, packaging.
As of 25 November 2026, Sfridoo has 6 published listings with waste code 15 01 10*. By legal classification: 6 as waste. Most frequent provinces: Padova (4) and Lodi (1).
It is produced by the chemical and paint industry, workshops, maintenance, agriculture, construction sites and anyone using hazardous products in packs. The asterisk marks it as hazardous, and it is the hazardous side of a «mirror» relationship with the non-hazardous entries 15 01 01 to 15 01 09: the same drum, cleaned and free of residue, falls for example under 15 01 02 if it is plastic or 15 01 04 if it is metal. Metallic packaging containing a dangerous solid porous matrix and empty pressure containers have entry 15 01 11* instead.
Managing waste with code 15 01 10*
It is hazardous waste. What makes it so is the residue, not the container: classification starts from the safety data sheet of the product contained and from the hazardous properties HP1 to HP15 of Annex III of Directive 2008/98/EC, as replaced by Regulation (EU) No 1357/2014. Storage limits are set by the Member State, and are usually tighter for hazardous waste; under the Landfill Directive (1999/31/EC), storing waste for more than three years before recovery, or more than one year before disposal, counts as landfilling. Storage is by homogeneous category, in closed containers labelled under art. 19 of the directive and the rules on dangerous substances, on an impermeable surface that contains any leaks.
Article 18 of Directive 2008/98/EC prohibits mixing hazardous waste with other categories of hazardous waste or with other waste, unless permitted: drums with different residues must therefore be kept apart. For hazardous waste, by-product status under art. 5 is rare, because it is hard to show that the use carries no risk to health and the environment. The ordinary route is cleaning at a permitted plant, after which the container can cease to be waste under art. 6 and go back into use.
Collecting this packaging is almost always a service rather than a sale, but reconditionable containers — steel and polyethylene drums, IBCs — have a market of their own. On Sfridoo every listing declares how the material is framed — waste, by-product or secondary raw material — because the obligations of whoever takes it follow from that.
Treatment and recovery
At the plant the first step is normally storage, R13 or D15 of Annexes II and I of Directive 2008/98/EC, followed by cleaning: removal of residues, washing, leak testing. The cleaned container can be reconditioned and become packaging again, or flaked or baled and sent to plastic recycling (R3) or metal recycling (R4). The outputs are reconditioned drums and IBCs, polyethylene regrind and scrap metal.
The residues removed and the washing water are new waste, with codes of their own, and go to physico-chemical treatment (D9), incineration (D10) or energy recovery (R1) according to their nature. Containers that cannot be cleaned, such as impregnated sacks or packaging with hardened residues, follow the same thermal route. Cleaning also decides the cost of the service: a drum properly emptied at source, closed and with a legible label, is easier to treat than one arriving with heavy residues or unknown contents. Landfill (D1) remains possible only at hazardous waste sites and under the acceptance criteria of Council Decision 2003/33/EC.
Regulatory obligations
Hazardous waste is controlled from production to final destination (art. 17 of Directive 2008/98/EC), and when it is moved within a Member State it is accompanied by an identification document, which may be electronic (art. 19(2)). The chronological record of art. 35 applies to every producer of hazardous waste, whatever its headcount: quantity, nature, origin, destination, collection frequency, mode of transport and treatment method, with the documents kept for at least three years. Any simplification for particular categories, such as farms producing small quantities, depends on national rules.
Member States may run electronic registries for these records and require annual reporting, and producers of hazardous waste are within their scope. Sending the containers to a plant in another country requires prior written notification and consent under Regulation (EU) 2024/1157 on shipments of waste, which applies from 21 May 2026 and replaces Regulation (EC) No 1013/2006.
Carriers must be registered with the competent authority under art. 26 of Directive 2008/98/EC, for hazardous waste; whether a producer may carry its own hazardous waste, and in what quantities, is set by national rules. Depending on the residue, transport may also fall under the ADR agreement on dangerous goods by road. The receiving plant must hold a permit under art. 23 covering hazardous waste and this code. Where the residue is unknown, analytical characterisation is necessary, and it is in any case what the plant asks for before accepting the load.
Other codes in sub-chapter 15 01
Published listings
- No photograph for this listingWaste
Frequently asked questions
Who collects packaging under code 15 01 10*?
Packaging under code 15 01 10*, that is packaging containing residues of or contaminated by dangerous substances — drums, jerrycans, intermediate bulk containers, paint tins, chemical sacks — is collected by plants authorised to treat hazardous waste and by operators who clean containers to recondition them or send them to plastic and metal recycling. The carrier must be registered for hazardous waste under art. 26 of Directive 2008/98/EC: this is not a collection just anyone can perform. Containers with different residues are best kept apart, because art. 18 of the directive prohibits mixing hazardous waste with other categories of hazardous waste unless permitted.
Does a well-emptied drum become non-hazardous again?
A drum under code 15 01 10* that has been emptied well does not become non-hazardous on its own: emptying is not enough, it has to be cleaned. If the container has been cleaned — residues removed, washed, checked — and no longer carries residues of dangerous substances or contamination, the correct code becomes 15 01 02 for plastic, or the code of its material. The assessment is made by the waste producer and must be documented, usually with a statement from the plant that did the cleaning: it is a change of code, not an administrative shortcut. The residues removed and the washing water are new waste, with codes of their own.
Why does the code carry an asterisk when the page address does not?
Code 15 01 10* carries an asterisk, but the page address does not, because an asterisk does not belong in a web path: it has to be encoded, it survives copying and emailing badly, and search engines normalise it in ways we do not control. That is why the address uses only the digits of the code. The asterisk does remain in the page text, in the title and in the structured data, where a person and a machine read it without ambiguity, and where it says what matters most: that 15 01 10* is hazardous waste, with stricter obligations than an entry without an asterisk.
Not finding what you are looking for?
Tell us which material you need: we also look among materials not yet published.
Do you have a residue your company does not use? Describe it: a Sfridoo technician checks it before it appears among the listings.