EWC code 10 01 18*
wastes from gas cleaning containing dangerous substances
Identification table for code 10 01 18*
- EWC code
- 10 01 18*
- Hazardous
- Yes: entry marked with an asterisk
- Sub-chapter
- 10 01 — Wastes from power stations and other combustion plants (except 19)
- Common name
- Hazardous residues from the flue gas treatment system of a combustion plant.
- Who produces it
- Thermal power stations, industrial combustion plants, cogeneration, large biomass boilers.
- Examples
- Spent dry scrubbing reagents, bag filter dust containing metals, spent activated carbon from flue gas treatment.
Code 10 01 18* sits in chapter 10, wastes from thermal processes, and in sub-chapter 10 01, power stations and other combustion plants. It covers wastes from gas cleaning containing dangerous substances; the non-hazardous mirror is 10 01 19. It does not cover everything that leaves a stack: coal fly ash has entry 10 01 02, and calcium-based reaction wastes from desulphurisation have entries 10 01 05 and 10 01 07.
As of 25 November 2026, Sfridoo has 1 published listing with waste code 10 01 18*. By legal classification: 1 as waste. Most frequent province: Torino (1).
The boundary with chapter 19 is the one to keep in mind: flue gas residues from a waste incinerator do not belong here, but in sub-chapter 19 01, under entry 19 01 07*. Chapter 10 applies to power stations and combustion plants, including when they co-incinerate. In 2022 the EU generated 2,225.7 million tonnes of waste across all economic activities and households, according to Eurostat, of which 229.4 million tonnes came from manufacturing.
A gas cleaning residue concentrates what the filter has retained: metals, salts, unreacted reagents. The usual destination is stabilisation or solidification (D9) followed by disposal in a landfill for hazardous waste, under the acceptance criteria of Council Decision 2003/33/EC; where a plant is permitted, part of the salts is recovered (R5). For hazardous waste, framing as a by-product under Article 5 of Directive 2008/98/EC is rare, and end-of-waste status under Article 6 comes, if at all, after recovery in a permitted plant. Classification follows the List of Waste, Commission Decision 2000/532/EC as amended by Decision 2014/955/EU, with the hazardous properties HP1 to HP15 of Annex III of the directive as replaced by Regulation (EU) No 1357/2014. Under Article 17 the waste is controlled from production to final destination, under Article 18 it may not be mixed with other waste unless permitted, and under Article 19 it is labelled and, when moved within a Member State, accompanied by an identification document, which may be electronic. Article 35 requires the producer to keep a chronological record of quantity, nature, origin, destination, collection frequency, mode of transport and treatment method; Member States may run electronic registries and set the annual reporting. Storage limits before collection are set by the Member State, while under the Landfill Directive 1999/31/EC storing waste for more than three years before recovery, or more than one year before disposal, counts as landfilling. The carrier must be registered under Article 26, and a shipment to another country follows Regulation (EU) 2024/1157 on shipments of waste, which applies from 21 May 2026.
Published listings
- Sludge and wastewater10 01 18*Sludge and wastewater25,000 kg/yearPrice on requestTorino (TO)Constant
Frequently asked questions
Who collects waste under code 10 01 18*?
Waste under code 10 01 18* is collected by plants authorised to stabilise and solidify hazardous waste (D9), by hazardous waste landfills for what remains after treatment, and by plants that recover salts from spent reagents (R5) where they are permitted to. A gas cleaning residue concentrates what the filter has captured, that is metals, salts and unreacted reagents, and the plant asks for a full analysis, including the leaching test under Council Decision 2003/33/EC when the final destination is a landfill. The carrier must be registered under Article 26 of Directive 2008/98/EC, and enabled for hazardous waste where national rules require it.
What is the difference between 10 01 18* and 10 01 19?
10 01 18* and 10 01 19 are mirror entries: 10 01 18* is gas cleaning waste containing dangerous substances, 10 01 19 the non-hazardous counterpart. Classification is made by the waste producer, through an analysis compared with the hazardous property criteria, and must be repeated when the fuel or the reagent changes, because they determine the metals and salts the filter retains. Flue gas from a waste incinerator falls under neither entry: its residues have entry 19 01 07* in chapter 19.
Does ash from a biomass boiler take this code?
No: ash from a biomass boiler does not take code 10 01 18*. Bottom ash, slag and boiler dust, and fly ash have entries of their own in the same sub-chapter 10 01, such as 10 01 01 and, for fly ash from peat and untreated wood, 10 01 03. Code 10 01 18* concerns only residues from the flue gas cleaning system, such as spent reagents and activated carbon, when they contain dangerous substances. The choice of entry therefore depends on where in the plant the residue is collected, and is made by whoever produces it.
Not finding what you are looking for?
Tell us which material you need: we also look among materials not yet published.
Do you have a residue your company does not use? Describe it: a Sfridoo technician checks it before it appears among the listings.